Deoxidation Furnaces Type FD


These furnaces are used to prevent surface oxidation on items during annealing operations and to deoxidise finished products. They ensure uniform thermal treatments. Thanks to the use of a protective gas, the items come out deoxidised and bright. A stainless steel water tank for rapid cooling operations is also included; by means of a manually operated or automatic lifting device, the items can be immersed in to this tank. The furnace is also fitted with a patented cooling chamber, entirely built in stainless steel, which prevents condensate from dripping onto the items during the treatment. An electronic timer counts down the deoxidation time only after the metal inside as reached the preset temperature. The muffle is made out of AISI 310S of a thickness of 6 and 4 mm, fitted with a loading door. There is also a gas burner with a safety device.

TECHNICAL DATA FD/G1 FD/H FD/A
Power Supply Three-Phase Three-Phase Three-Phase
Power 5 kW 7 kW 11 kW
Propane Gas Consumption (l/h) 300 300 500
Hydrogen/Nitrogen Gas Consumption (l/h) 150 250 400
Average Thickness of Stainless Steel Muffle 3.5 mm 5 mm 5 mm
Useful Dimensions of the Muffle (mm) 220×100 220×10 300×150
Length of Heated Zone (mm) 270 480 600
Lifting Device Manual Manual Manual
Overall Dimensions (mm) 1700x650x1700 2120x930x1645 2430x1080x1745
Weight 240 kg 424 kg 740 kg
FD/D FD/E FD/E2
Power Supply Three-Phase Three-Phase Three-Phase
Power 17 kW 30 kW 30 kW
Propane Gas Consumption (l/h) 600 500-800 500-800
Hydrogen/Nitrogen Gas Consumption (l/h) 600 500-800 500-800
Average Thickness of Stainless Steel Muffle 7 mm 9 mm 9 mm
Useful Dimensions of the Muffle (mm) 416X190 550X225 550X225
Length of Heated Zone (mm) 800 1200 1200
Lifting Device Motorized Motorized Motorized
Overall Dimensions (mm) 1400x2800x2060 1800x4000x2000 1800x5600x2000
Weight 800 kg 2300 kg 2500 kg

The furnace is a thermal treatment centre for the finishing of all articles made out of a gold alloy. It improves the uniformity of the colour and obtains shinier pieces. A stainless steel water tank for rapid cooling operations is also included; by means of a manually operated or automatic lifting device, the items can be immersed in to this tank. The furnace has a patented cooling chamber, made entirely out of stainless steel, which stops condensate from falling onto the pieces to be annealed or deoxidised. An electronic timer counts down the deoxidation time only after the metal inside as reached the preset temperature. The muffle is made out of AISI 310S of a thickness of 6 and 4 mm, fitted with a loading door. There is also a gas burner with a safety device and two closing gates to separate the two heating zones.The furnace has been designed to reduce annealing and deoxidation times by 50 %. 5 kgs of finished products can be treated every 20 minutes.

TECHNICAL DATA FD/CV
Power Supply Three-Phase
Power (3 heated zones of 7 kW each) 21 kW
Propane Gas Consumption (l/h) 700
Cracked Ammonia Consumption (l/h) 800
Min Pressure of Compressed Air 5 bar
Working Temperature 850 °C
Muffle Dimensions (mm) 260×80
Length of the 2 Heating Zones (mm) 660
Lower Muffle for Oxidation (mm) 260x80x660
Overall Dimensions (mm) 850x3000x1900

FURNACES FOR SPECIAL HEAT TREATMENTS

TECHNICAL DATA FD/DR FD/E700 FD/R1
Power Supply Three-Phase Three-Phase Three-Phase
Power 30 kW 40 kW 11.2 kW
Propane Gas Consumption (l/h) 600 900 500
Hydrogen/Nitrogen Gas Consumption (l/h) 600 900 500
Average Thickness of Stainless Steel Muffle 7 mm 9 mm 6 mm
Useful Dimensions of the Muffle (mm) 416×190 700×262 320×120
Length of Heated Zone (mm) 960 1200 685
Overall Dimensions (mm) 1400x2800x2060 2100x4000x2000 3250x100x1950
Weight 800 kg 2800 kg 800 kg


DOWNLOAD DATA SHEET (PDF)